Determination of metronidazole by a flow-injection chemiluminescence method using ZnO-doped carbon quantum dots
-
Graphical Abstract
-
Abstract
ZnO-doped carbon quantum dots (CQDs) were prepared by the chemical oxidation of activated carbon followed by zinc acetate impregnation and precipitation. The ZnO-doped CQDs had a stable fluorescence and a high fluorescence quantum yield. The fluorescence of the ZnO-doped CQDs can be quenched by reduction with metronidazole, allowing a flow-injection chemilumi-nescence method to be used to determine the metronidazole content in tablets. Under optimum conditions, there was a good linear relation between the concentration of metronidazole and the intensity of chemiluminiscence. The linear concentration range examined was 7. 5×10 -4 -2. 5×10 -8 g/ mL with r = 0. 999 6 and a detection limit of 1. 08×10 -10 g/ mL.
-
-